AC Size Calculator: What Size Air Conditioner Do I Need?

To size a room air conditioner by hand or with the AC size calculator below, find the room's square footage on the ENERGY STAR sizing chart, then adjust. Add 10 percent for a very sunny room or subtract 10 percent for a heavily shaded one, add 600 BTU for each person beyond two who regularly uses the room, and add 4,000 BTU for a kitchen. A 15 × 12 ft bedroom (180 sq ft) needs about 6,000 BTU.

Don't round up "just to be safe." An oversized unit cools the air before it pulls out the humidity, which leaves the room clammy. Enter your room below to get the right size.

What size air conditioner do you need?

Enter the room size and how many people use it, then tick any that apply.

ft
ft
people

Based on the ENERGY STAR room air conditioner sizing chart. Ceilings over 8 ft, poor insulation, or hot climates may need more.

How to measure the room

  1. Measure length and width in feet. Measure the space the unit has to cool. If an area opens onto the room without a door, like a dining nook off a living room, include it, since the air conditioner will be cooling it too.
  2. Split odd shapes into rectangles. Add them up with our square footage calculator. Then enter the total square footage as the length and 1 as the width.
  3. Count the people who regularly use the room. ENERGY STAR's adjustment applies to people who regularly occupy it, not occasional guests.
  4. Note the sun. Tick "Room gets a lot of sun" for a room with strong sun exposure, or "Room is heavily shaded" if trees or buildings block most direct sun. If you tick both, the calculator applies neither.
  5. Check the window and the outlet. ENERGY STAR notes that window models fit most double-hung windows, casement models for narrow vertical windows usually require removing a window panel, and built-in models go in a sleeve in the wall. Measure the opening before you shop.
Room AC size from floor areaPlan of a 15 by 12 foot room, 180 square feet, used by 2 people. On the ENERGY STAR room air conditioner sizing chart, 150 up to 250 square feet calls for 6,000 BTU.ROOM AC SIZE STARTS WITH FLOOR AREA180 sq ft15 ft12 ftENERGY STAR sizing chartexcerpt, area to be cooled100 up to 150 sq ft5,000 BTU150 up to 250 sq ft6,000 BTU250 up to 300 sq ft7,000 BTU300 up to 350 sq ft8,000 BTUArea: 15 ft × 12 ft = 180 sq ft180 falls in the 150 up to 250 sq ft row → 6,000 BTU2 people and no sun, shade, or kitchen changes: 6,000 BTU
Multiply length by width for floor area, then find that row on the ENERGY STAR chart: 180 sq ft calls for 6,000 BTU.

The formula

The calculator uses:

  • Area = room length × room width
  • Base BTU = the ENERGY STAR chart value for that area
  • Sunny room: base × 1.10. Heavily shaded room: base × 0.90
  • People: + 600 BTU for each regular occupant beyond 2
  • Kitchen: + 4,000 BTU
  • The result is rounded to the nearest BTU

When the area falls exactly on a chart boundary, such as 150 sq ft, the calculator uses the smaller size. Rooms over 2,500 sq ft are beyond the chart, and the calculator suggests central air or multiple units.

Worked example (the calculator's default values)

A 15 × 12 ft room used by 2 people, with no sun, shade, or kitchen adjustment:

  1. Area: 15 × 12 = 180 sq ft
  2. Chart: 180 sq ft falls in 150 up to 250 sq ft, so the base is 6,000 BTU
  3. Adjustments: none (2 people is the chart's baseline)
  4. Result: 6,000 BTU

The calculator shows: "Look for an air conditioner rated about 6,000 BTU. Room: 180 sq ft (chart base 6,000 BTU)."

The same room with adjustments

If that room gets strong afternoon sun and 3 people use it regularly, the math is 6,000 × 1.10 = 6,600, plus 600 for the third person = 7,200 BTU. The calculator lists the adjustments: "Room: 180 sq ft (chart base 6,000 BTU), +10% for sun, +600 BTU for 1 extra person."

Room units come in set capacities, so pick the model closest to your result rather than jumping up a size or two. The adjustments already account for sun, shade, people, and cooking, and the next section explains why extra capacity works against you.

Adjusting the AC chart number for your roomFour adjustments to the 6,000 BTU chart number: a very sunny room adds 10 percent (6,600 BTU), a heavily shaded room subtracts 10 percent (5,400 BTU), each person over 2 adds 600 BTU, and a kitchen adds 4,000 BTU (10,000 BTU).ADJUST THE CHART NUMBERStart with the chart number: 6,000 BTU for the 15 × 12 ft room.Very sunny room+10%6,000 → 6,600 BTUHeavily shaded−10%6,000 → 5,400 BTUEach person over 2+600 BTU3 people → 6,600 BTUKitchen+4,000 BTU6,000 → 10,000 BTUApply the percent change first, then add BTU for people and kitchens.Example: sunny kitchen used by 3 people6,000 × 1.10 = 6,600, + 600 + 4,000 = 11,200 BTU
Adjust the chart number for sun or shade first, then add 600 BTU for each regular occupant beyond two and 4,000 BTU for a kitchen.

ENERGY STAR room air conditioner sizing chart

Area to be cooledCapacity neededExample room
100 up to 150 sq ft5,000 BTU10 × 12 ft (120 sq ft)
150 up to 250 sq ft6,000 BTU12 × 15 ft (180 sq ft)
250 up to 300 sq ft7,000 BTU15 × 18 ft (270 sq ft)
300 up to 350 sq ft8,000 BTU16 × 20 ft (320 sq ft)
350 up to 400 sq ft9,000 BTU18 × 20 ft (360 sq ft)
400 up to 450 sq ft10,000 BTU20 × 21 ft (420 sq ft)
450 up to 550 sq ft12,000 BTU20 × 25 ft (500 sq ft)
550 up to 700 sq ft14,000 BTU25 × 25 ft (625 sq ft)
700 up to 1,000 sq ft18,000 BTU30 × 30 ft (900 sq ft)
1,000 up to 1,200 sq ft21,000 BTU30 × 36 ft (1,080 sq ft)
1,200 up to 1,400 sq ft23,000 BTU35 × 38 ft (1,330 sq ft)
1,400 up to 1,500 sq ft24,000 BTU30 × 48 ft (1,440 sq ft)
1,500 up to 2,000 sq ft30,000 BTU40 × 45 ft (1,800 sq ft)
2,000 up to 2,500 sq ft34,000 BTU45 × 50 ft (2,250 sq ft)

Adjustments

ConditionENERGY STAR adjustmentOn a 6,000 BTU base
Heavily shaded roomReduce capacity by 10%5,400 BTU
Very sunny roomIncrease capacity by 10%6,600 BTU
More than 2 regular occupantsAdd 600 BTU per extra person6,600 BTU with 3 people
Unit used in a kitchenAdd 4,000 BTU10,000 BTU

Why bigger isn't better

ENERGY STAR puts it plainly: if the unit is too large, it cools the room before it has a chance to remove the humidity, and cool, moist air feels damp and clammy. An oversized unit also costs more to buy, wastes energy, and doesn't cool any better. The Department of Energy's heating and cooling guide adds that oversized systems can be noisy and can lead to mold and poor indoor air quality.

An undersized unit has the opposite problem: it can struggle to keep up on the hottest days. That's why getting the adjustments right matters more than rounding up.

Room, portable, or central air?

  • Window and through-the-wall units. This is what the ENERGY STAR chart is built for.
  • Portable units. Their boxes can show two ratings. According to Honeywell, the Department of Energy introduced the SACC (seasonally adjusted cooling capacity) rating in October 2017. It's measured under warmer, more realistic conditions than the older ASHRAE number, so it comes out lower. Compare the SACC figure with your result.
  • Central air and heat pumps. Whole-house systems need a load calculation. The Department of Energy recommends insisting that your contractor use ACCA Manual J to size the equipment.

Installation and efficiency tips

  • Check the voltage before you buy. ENERGY STAR notes that a standard household outlet is on a 115-volt circuit, large 115-volt units may need a dedicated circuit, and 230-volt units may need a special circuit.
  • Seal the install. ENERGY STAR says an improperly installed room air conditioner leaks as much air as a 6 square inch hole. Use the insulation materials that come with the unit.
  • Keep heat away from the thermostat. ENERGY STAR advises against placing lamps or TVs near the unit's thermostat, since the extra heat makes it run longer.
  • Use the fan settings. ENERGY STAR suggests an extra fan to spread the cooled air around, and a low fan speed on humid days, because slower air movement removes more moisture.
  • Compare efficiency. ENERGY STAR's criteria for room units are written in CEER (combined energy efficiency ratio), measured in BTU per watt-hour. Between two units of the right size, the one with the higher CEER uses less electricity for the same cooling.

Common mistakes

  • Sizing for the whole floor. If the door stays closed, size for the room. If it opens onto other spaces, include them.
  • Counting guests as occupants. Only add people who use the room regularly.
  • Skipping the kitchen adjustment. A kitchen needs 4,000 BTU more than a bedroom of the same size.
  • Buying a portable unit by its larger number. Use the SACC rating.
  • Treating the chart as exact. It's a starting point based on floor area. The Department of Energy points out that area-based rules of thumb don't take into account local climate or how well a house is sealed and insulated, so a leaky, poorly insulated room or a very hot climate may need more than the chart shows. That's a reason to lean toward the upper size, not to jump several sizes.

Frequently asked questions

What size air conditioner do I need for a 12 × 12 room?

A 12 × 12 room is 144 sq ft, which falls in the ENERGY STAR range of 100 up to 150 sq ft, so about 5,000 BTU. Add 10 percent if it gets a lot of sun, or 600 BTU for each regular occupant beyond two.

How many square feet will a 10,000 BTU air conditioner cool?

On the ENERGY STAR chart, 10,000 BTU matches rooms of 400 up to 450 sq ft. In a very sunny room, the same unit covers less area, and in a heavily shaded one, a bit more.

How many BTU do I need for 500 square feet?

About 12,000 BTU, the chart value for 450 up to 550 sq ft, before any adjustments for sun, shade, people, or a kitchen.

Is a bigger air conditioner better?

No. ENERGY STAR says an oversized unit cools the room before it removes the humidity, leaving it damp and clammy, and that it costs more, wastes energy, and doesn't cool any better.

Why does a kitchen need a bigger air conditioner?

Cooking adds heat. ENERGY STAR recommends adding 4,000 BTU if the unit will be used in a kitchen, so a 168 sq ft kitchen goes from 6,000 to 10,000 BTU.

Does this work for central air?

No. It's for room units. For central air or a heat pump, the Department of Energy recommends insisting that your contractor use ACCA Manual J to calculate the right size.