Furnace Size Calculator: What Size Furnace Do I Need?

A common rule of thumb from HVAC maker Bryant puts a 2,000 sq ft home in a moderate climate at 80,000 to 100,000 BTU/h of heat. At 95% AFUE, that's a furnace input of about 84,200 to 105,300 BTU/h.

What size furnace do you need?

Enter the floor area your furnace heats and pick your climate for a rule-of-thumb estimate, or enter the heat loss from a Manual J load calculation if you have one. The AFUE turns the heat your home needs (the output) into the furnace input rating.

sq ft
%
BTU/h

A rough estimate, not a sizing: a Manual J load calculation by a licensed HVAC contractor should set the furnace size. The climate figures are Bryant's rule of thumb (30 to 60 BTU per sq ft). An oversized furnace short-cycles. Have gas work done by a pro, and keep CO alarms on every level of the home.

By hand, multiply the heated floor area by Bryant's BTU per square foot for your climate, then divide by the AFUE to get the input rating.

Treat that as a starting point, not the size to buy. A Manual J load calculation, which ACCA says national building codes require, is what a licensed HVAC contractor should size your furnace from. Have one? Enter its heat loss above, and our furnace size calculator gives the output and input to look for.

How to use the furnace size calculator

  1. Enter the heated floor area in square feet: the finished rooms the furnace heats. The square footage calculator adds up rooms for you.
  2. Pick your climate. These are Bryant's three regions: warm (South, Southwest), moderate (Midwest, Mid-Atlantic), and cold (Northeast, northern Midwest). Near a boundary, run both and compare.
  3. Enter the AFUE from the furnace's spec sheet. The default, 95%, is the lowest AFUE ENERGY STAR certifies for a gas furnace (in the U.S. South). Try 80 for a standard model.
  4. Add a Manual J heat loss if you have one, in BTU/h, from your contractor's load calculation. Leave 0 to use the rule of thumb.

The furnace size formula

  • Heat needed (furnace output) = heated area (sq ft) × BTU per sq ft for your climate
  • Furnace input = output × 100 ÷ AFUE
  • With a Manual J heat loss: output to look for = heat loss to 1.4 × heat loss; input = output × 100 ÷ AFUE
  • Results are rounded to the nearest 100 BTU/h

Bryant's guide says "a simple way to estimate furnace size is to multiply your home's square footage by 30 to 60 BTUs per square foot," and that "homes in colder climates require higher BTU output." The calculator reads those figures as output, the heat delivered to the house. AFUE links output to input: "a furnace with 80% AFUE delivers 80% of its input BTUs as heat," in Bryant's words. The Department of Energy (DOE) adds that at 90% AFUE, the other 10% escapes up the chimney and elsewhere.

Worked example (the calculator's default values)

A 2,000 sq ft home in a moderate climate, a 95% AFUE furnace, and no Manual J figure:

  1. Heat needed: 2,000 × 40 = 80,000 BTU/h at the low end, and 2,000 × 50 = 100,000 BTU/h at the high end.
  2. Input: 80,000 × 100 ÷ 95 = 84,210.5, rounded to 84,200 BTU/h; 100,000 × 100 ÷ 95 = 105,263.2, rounded to 105,300 BTU/h.

The calculator shows: "Estimated heat needed: 80,000 to 100,000 BTU/h of furnace output, or about 84,200 to 105,300 BTU/h input at 95% AFUE." and "Rule of thumb for a moderate climate (Midwest, Mid-Atlantic): 2,000 sq ft x 40 to 50 BTU per sq ft. Input = output x 100 / 95. Furnaces come in size steps: compare these figures with the output and input on the spec sheet."

With a Manual J heat loss

Say a contractor's Manual J puts the same house at a 60,000 BTU/h heat loss (an example figure). ENERGY STAR's rules for new homes allow a heating-only furnace an output of 100% to 140% of the heat loss, so the calculator shows: "For a 60,000 BTU/h heat loss, look for a furnace output of about 60,000 to 84,000 BTU/h, or 63,200 to 88,400 BTU/h input at 95% AFUE."

Furnace size for a 2,000 square foot home in a moderate climateA 2,000 square foot home times 40 to 50 BTU per square foot, a rule of thumb for a moderate climate, equals 80,000 to 100,000 BTU per hour of heat needed. That is the furnace output. A furnace burns gas (the input) and sends warm air to the supply duct (the output); at 95 percent AFUE, 95 percent of the input becomes heat for the home and the other 5 percent is lost up the vent and elsewhere. So the input is the output times 100 divided by 95: about 84,200 to 105,300 BTU per hour. With a Manual J heat loss, look for an output of 100 to 140 percent of it.FURNACE SIZE: 2,000 SQ FT, MODERATE CLIMATE2,000 sq ftheated floor area×40 to 50BTU per sq ft, moderate=80,000 to 100,000BTU/h heat needed (output)95% AFUEGas in (input)84,200 to 105,300 BTU/h= output × 100 ÷ 95Heat to the house (output)80,000 to 100,000 BTU/h95% of the inputthe other 5%: vent and elsewhereHeat needed: 2,000 sq ft × 40 to 50 = 80,000 to 100,000 BTU/hInput at 95% AFUE: output × 100 ÷ 95 = 84,200 to 105,300 BTU/hManual J heat loss? Look for an output of 100% to 140% of it
2,000 sq ft × 40 to 50 BTU per sq ft (Bryant's rule of thumb for a moderate climate) = 80,000 to 100,000 BTU/h of heat, the furnace output. At 95% AFUE, 95% of the gas input becomes heat for the home, so the input is the output × 100 ÷ 95: about 84,200 to 105,300 BTU/h. With a Manual J heat loss, look for an output of 100% to 140% of it.

Furnace size chart by square footage

Heat needed (furnace output) in BTU/h, using Bryant's BTU per square foot. Bryant's own chart covers 1,000 to 2,500 sq ft; the other rows use the same figures. Divide by the AFUE for the input.

Heated areaWarm (30 to 35 per sq ft)Moderate (40 to 50)Cold (50 to 60)
1,000 sq ft30,000 to 35,00040,000 to 50,00050,000 to 60,000
1,200 sq ft36,000 to 42,00048,000 to 60,00060,000 to 72,000
1,500 sq ft45,000 to 52,50060,000 to 75,00075,000 to 90,000
1,800 sq ft54,000 to 63,00072,000 to 90,00090,000 to 108,000
2,000 sq ft60,000 to 70,00080,000 to 100,000100,000 to 120,000
2,500 sq ft75,000 to 87,500100,000 to 125,000125,000 to 150,000
3,000 sq ft90,000 to 105,000120,000 to 150,000150,000 to 180,000

Rules of thumb don't agree. Carrier's reference table lists 50,000 to 60,000 BTU/h as a "common range for many medium-sized homes" of 1,000 to 2,000 sq ft, well below Bryant's figures, and calls its ranges "not equipment-sizing recommendations." Carrier also says square footage alone should not be used to determine the correct furnace size.

Furnace size chart by climate zone

Zones 1 to 8, from the hottest counties to the coldest, make up the climate zone map of the International Energy Conservation Code (IECC), and a Department of Energy guide lists the zone of every U.S. county. DOE's county guide puts the cold zones 5 and 6 at 5,400 to 9,000 heating degree days (65°F base), very cold zone 7 at 9,000 to 12,600, and subarctic zone 8, found only in Alaska, at 12,600 or more; the mixed climates of zones 3 and 4 have about 5,400 or fewer. The letter after the number is moisture: A for moist, B for dry, C for marine.

Bryant's three regions, which the calculator uses, are named by area, not by zone, and they don't follow zone numbers: zone 5 takes in most of Illinois (Midwest, so moderate) and Albany and Erie counties in New York (Northeast, so cold). Pick the calculator's climate by region, and use the zone to see how cold your county runs. Examples from DOE's county guide, with the Bryant region each falls in and the heat output for a 2,000 sq ft home:

IECC zoneExample counties (DOE county guide)Bryant regionOutput per sq ft (2,000 sq ft home)
1AMiami-Dade, Broward, and Monroe, FloridaWarm (South)30 to 35 (60,000 to 70,000 BTU/h)
2BMaricopa and Pima, ArizonaWarm (Southwest)30 to 35 (60,000 to 70,000 BTU/h)
3AMost of GeorgiaWarm (South)30 to 35 (60,000 to 70,000 BTU/h)
4AAll of Maryland except GarrettModerate (Mid-Atlantic)40 to 50 (80,000 to 100,000 BTU/h)
5AMost of Illinois and IowaModerate (Midwest)40 to 50 (80,000 to 100,000 BTU/h)
5AAlbany and Erie, New YorkCold (Northeast)50 to 60 (100,000 to 120,000 BTU/h)
6AHennepin, Minnesota; most of MaineCold (northern Midwest, Northeast)50 to 60 (100,000 to 120,000 BTU/h)
7St. Louis, Minnesota; Aroostook, MaineCold (northern Midwest, Northeast)50 to 60 (100,000 to 120,000 BTU/h)
8Fairbanks North Star and North Slope, AlaskaNone of the threeNo rule of thumb: get a Manual J

Zone 7, at 9,000 to 12,600 heating degree days, is colder than zones 5 and 6, so start from the high end of the cold band there; Bryant notes that colder climates require higher BTU output. Alaska isn't in any of Bryant's regions, and every zone line is drawn by county, so in the far north and near a zone line, a Manual J settles the size. Your building department can confirm your county's zone.

Input vs. output: reading a furnace spec sheet

A furnace has two BTU ratings. Input is the fuel it burns per hour; output (heating capacity) is the heat that reaches your ducts. Spec sheets list both. Two Goodman model lines show how the AFUE links them:

Input (BTU/h)Output, 80% AFUE line (GM9S80)Output, 96% AFUE line (GM9S96)
40,00032,00038,440
60,00048,00057,660
80,00064,00076,880
100,00080,00096,100
120,00096,000115,320

Both lines come in steps of 20,000 BTU/h of input, so you pick the step whose output fits your number. For the default example (80,000 to 100,000 BTU/h of output), the 96% line's 100,000 input model, with 96,100 of output, lands inside the range; its 80,000 model, at 76,880, falls just below. Always compare output with output: two furnaces with the same 80,000 BTU/h input deliver 64,000 and 76,880 BTU/h. On propane, the input is what empties the tank: the propane usage calculator turns it into gallons a day and days per tank.

How to tell what size furnace you have

80,000 BTU/h of input is what the 080 means in a Goodman model number such as GM9S960803BN. Trane says to find the manufacturer's sticker or plate on the side of the furnace and look up the brand and model number; on Trane furnaces, it adds, the BTU is the middle number, such as 040, 060, 080, 100, or 120. Goodman's spec sheets decode the whole model number:

Part of GM9S960803BNWhat it means
GGoodman brand
MUpflow or horizontal (C is downflow or horizontal)
9Nine-speed ECM blower motor
SSingle-stage gas valve (C is two-stage)
9696% AFUE
08080,000 BTU/h input
3Blower airflow up to 1,200 CFM (4 is 1,600 and 5 is 2,000)
B17.5 in wide cabinet

In Goodman's code that number is the input, not the heat delivered: the spec sheet lists 76,880 BTU/h of output for the same model. Other brands code their model numbers differently, so check yours against the maker's spec sheet, which lists both input and output.

How many square feet does each furnace size heat?

40,000 to 120,000 BTU/h covers most home furnaces. Bryant says most residential furnaces range from 40,000 to 120,000+ BTUs, Carrier says its typical gas furnaces run from about 44,000 to 120,000 BTU/h, and both Goodman lines above come in 20,000 BTU/h steps of input across that span. The floor area, in square feet, that each Goodman model's output covers at Bryant's BTU per sq ft (rounded to the nearest 10):

Input (BTU/h)Output (AFUE)Warm (30 to 35 per sq ft)Moderate (40 to 50)Cold (50 to 60)
40,00032,000 (80%)910 to 1,070640 to 800530 to 640
40,00038,440 (96%)1,100 to 1,280770 to 960640 to 770
60,00048,000 (80%)1,370 to 1,600960 to 1,200800 to 960
60,00057,660 (96%)1,650 to 1,9201,150 to 1,440960 to 1,150
80,00064,000 (80%)1,830 to 2,1301,280 to 1,6001,070 to 1,280
80,00076,880 (96%)2,200 to 2,5601,540 to 1,9201,280 to 1,540
100,00080,000 (80%)2,290 to 2,6701,600 to 2,0001,330 to 1,600
100,00096,100 (96%)2,750 to 3,2001,920 to 2,4001,600 to 1,920
120,00096,000 (80%)2,740 to 3,2001,920 to 2,4001,600 to 1,920
120,000115,320 (96%)3,290 to 3,8402,310 to 2,8801,920 to 2,310

Input alone doesn't tell you the area: at 80,000 BTU/h of input, the 96% model's output covers about a fifth more floor than the 80% model's, and a 100,000 BTU/h furnace at 96% covers about the same area as a 120,000 BTU/h furnace at 80%. When your house falls between two rows, let a Manual J decide.

Why a Manual J load calculation should set the size

ACCA calls Manual J "the national ANSI-recognized standard for producing HVAC equipment sizing loads" for homes, and DOE's heating and cooling guide says: "Insist that your contractor use the Air Conditioning Contractors of America (ACCA) Manual J to calculate the proper size of heating and cooling equipment."

A load calculation looks at what a square-foot rule can't. Carrier lists "the number and efficiency of windows, insulation levels, home orientation, ceiling heights, air leakage and the local climate." Bryant notes that a well-insulated, sealed home needs fewer BTUs and that ceilings above the standard 8 ft can need more; it gives no factor, so the calculator doesn't adjust for either. ENERGY STAR's HVAC design report for new homes uses room-by-room Manual J loads and a heating design temperature for the home's county.

That report also caps the furnace's output at 100% to 140% of the heat loss when it only heats. Paired with cooling, 100% to 140% is recommended and up to 400% is allowed.

DOE suggests improving the house first, with insulation or efficient windows, then having a heating contractor size the furnace. The attic insulation calculator shows how much ENERGY STAR recommends adding to an attic.

Oversized vs. undersized furnaces

Carrier says oversized furnaces heat too quickly and cycle on and off frequently (short cycling), which "can contribute to uneven temperatures, higher maintenance costs, reduced efficiency, and increased wear on system components." Undersized units "run continuously without adequately heating the home." Pick the step that fits the range; don't round up.

Signs of an oversized or undersized furnace

Short cycling points to too many BTUs, and running nonstop without reaching the thermostat setting to too few. The signs Bryant lists:

Oversized (too many BTUs)Undersized (too few BTUs)
Short cycles (turns on and off frequently)Runs constantly without reaching the set temperature
Uneven temperatures and poor humidity controlCold spots and inconsistent comfort
Increased wear and tear on componentsAdded strain that can shorten system lifespan
Wastes energy through inefficient operationStruggles to keep up in cold weather

More than 140% of the heat loss is oversized by ENERGY STAR's rule for a heating-only furnace in a new home. With the 60,000 BTU/h heat loss from the Manual J example above, a 100,000 BTU/h input furnace at 96% AFUE (96,100 output) comes to 160%, too big by that rule, while the 80,000 BTU/h model (76,880 output) comes to 128%. To know which side your furnace is on, you need the heat loss from a Manual J.

Furnace efficiency: AFUE and the input you need

A higher AFUE doesn't change the heat your home needs; it lowers the input that produces it. The input for the default example's 80,000 to 100,000 BTU/h of output:

AFUEInput for 80,000 BTU/h outputInput for 100,000 BTU/h output
80%100,000125,000
90%88,900111,100
95%84,200105,300
96%83,300104,200
97%82,500103,100
98.5%81,200101,500
AFUEWhat it isSource
56% to 70%Older, low-efficiency heating systemsDOE
80%What U.S. natural gas furnaces generally must deliverCarrier
90% to 98.5%High-efficiency heating systemsDOE
95% or moreENERGY STAR gas furnaces, U.S. South (e.g., Texas, Florida, California)ENERGY STAR
97% or moreENERGY STAR gas furnaces, U.S. North (e.g., Illinois, New York, Pennsylvania)ENERGY STAR

Gas furnace safety and carbon monoxide

DOE warns that a leaking furnace heat exchanger mixes combustion gases with house air, which can cause carbon monoxide poisoning, an important reason to have it inspected. It also suggests a sealed combustion furnace, which brings outside air directly to the burner and sends flue gases directly outside.

The Consumer Product Safety Commission (CPSC) recommends a professional inspection and service of the heating system every year, and carbon monoxide alarms meeting UL 2034 on every level of the home and outside sleeping areas. If an alarm sounds, move outside to fresh air immediately and call 911 or the fire department.

Replacing a gas furnace involves gas piping, venting, and wiring: hire a licensed HVAC contractor and get any permit your local code requires.

Tips and common mistakes

  • Mixing up input and output. Compare the calculator's output range with the furnace's output (heating capacity).
  • Copying the old furnace's size. It shows what was installed, not what the house needs now after new insulation or windows.
  • Forgetting other heat sources. Carrier lists supplemental heat, such as fireplaces and wood-burning stoves, among the factors that affect furnace size. If you burn wood, the firewood calculator tells you how many cords are in your stack; for an electric space heater, the electricity cost calculator shows the kWh it uses.
  • Sizing the air conditioner the same way. Cooling has its own load. For a single room with a window unit, the AC size calculator uses ENERGY STAR's room chart.

Frequently asked questions

What size furnace do I need for a 1,500 sq ft house?

About 60,000 to 75,000 BTU/h of heat output in a moderate climate by Bryant's rule of thumb, 45,000 to 52,500 in a warm climate, and 75,000 to 90,000 in a cold one. At 80% AFUE, the moderate range means an input of 75,000 to 93,800 BTU/h; of the Goodman models above, the 80,000 BTU/h input furnace at 80% AFUE (64,000 output) falls inside it. Let a Manual J set the final size.

What size furnace do I need for a 2,000 sq ft house?

By Bryant's rule of thumb, about 60,000 to 70,000 BTU/h of heat output in a warm climate, 80,000 to 100,000 in a moderate one, and 100,000 to 120,000 in a cold one. Divide by the AFUE for the input, and let a Manual J set the final size.

What size furnace do I need for a 2,500 sq ft house?

About 100,000 to 125,000 BTU/h of heat output in a moderate climate by Bryant's rule of thumb, 75,000 to 87,500 in a warm climate, and 125,000 to 150,000 in a cold one. The cold range is above the 115,320 BTU/h output of the largest Goodman model above (120,000 BTU/h input at 96% AFUE), and Carrier's typical gas furnaces go up to about 120,000 BTU/h. At this size, and above all in a cold climate, get a Manual J load calculation before you choose.

What size furnace do I need?

Multiply the heated square feet by Bryant's 30 to 35 BTU per sq ft in a warm climate, 40 to 50 in a moderate one, or 50 to 60 in a cold one for the heat output, then divide by the AFUE for the input. A 1,500 sq ft home in a moderate climate comes to 60,000 to 75,000 BTU/h of output, or about 63,200 to 78,900 BTU/h input at 95% AFUE (75,000 to 93,800 at 80%). That's a starting point; a Manual J load calculation sets the size.

How many BTUs does a furnace need per square foot?

30 to 60 BTU per sq ft of heat output by Bryant's rule of thumb: 30 to 35 in a warm climate (South, Southwest), 40 to 50 in a moderate one (Midwest, Mid-Atlantic), and 50 to 60 in a cold one (Northeast, northern Midwest). Those are output figures; at 80% AFUE the input comes to 37.5 to 75 BTU per sq ft. Carrier says square footage alone should not determine the size, so use them as a first estimate.

How many square feet will a 60,000 BTU furnace heat?

About 1,150 to 1,440 sq ft in a moderate climate, if 60,000 BTU/h is the input of a 96% AFUE furnace: Goodman rates that model at 57,660 BTU/h of output, which by Bryant's rule of thumb covers 1,650 to 1,920 sq ft in a warm climate and 960 to 1,150 in a cold one. At 80% AFUE (48,000 output), it's 960 to 1,200 sq ft in a moderate climate. Bryant's own FAQ says a 60,000 BTU furnace generally covers about 1,200 to 2,000 sq ft.

How many square feet will an 80,000 BTU furnace heat?

Check whether 80,000 is the input or the output. Goodman lists 76,880 BTU/h of output for an 80,000 BTU/h input at 96% AFUE. By Bryant's rule of thumb, that matches roughly 2,200 to 2,560 sq ft in a warm climate, 1,540 to 1,920 in a moderate one, and 1,280 to 1,540 in a cold one.

How many square feet will a 100,000 BTU furnace heat?

About 1,920 to 2,400 sq ft in a moderate climate, if 100,000 BTU/h is the input of a 96% AFUE furnace: Goodman rates that model at 96,100 BTU/h of output, which by Bryant's rule of thumb covers 2,750 to 3,200 sq ft in a warm climate and 1,600 to 1,920 in a cold one. At 80% AFUE (80,000 output), it's 1,600 to 2,000 sq ft in a moderate climate.

Is it better to get a bigger furnace?

No. Carrier says an oversized furnace short cycles, which can mean uneven temperatures, higher maintenance costs, and more wear. ENERGY STAR's new-home rules cap a heating-only furnace at 140% of the heat loss.

What is the difference between furnace input and output BTU?

Input is the fuel the furnace burns per hour; output is the heat it delivers. Output is about input times the AFUE: Goodman lists 48,000 BTU/h of output for a 60,000 BTU/h input at 80% AFUE, and 57,660 at 96%.

Do I need a Manual J calculation to replace a furnace?

ACCA says a proper Manual J load calculation is required by national building codes and most state and local jurisdictions, and the Department of Energy tells homeowners to insist their contractor use it. Ask your building department what it requires.

What size furnace and AC do I need?

Size each one for its own load: DOE says to insist that your contractor use ACCA Manual J "to calculate the proper size of heating and cooling equipment." For a first estimate, Bryant's rule gives the furnace output (60,000 to 75,000 BTU/h for 1,500 sq ft in a moderate climate), and the AC size calculator gives cooling BTU from ENERGY STAR's room chart. For a furnace paired with central air, ENERGY STAR's new-home rules recommend 100% to 140% of the heat loss and allow up to 400%.

What AFUE should a new gas furnace have?

Carrier says U.S. natural gas furnaces generally must deliver at least 80% AFUE. ENERGY STAR certifies gas furnaces at 95% or more in the U.S. South and 97% or more in the U.S. North.